Your current location:HOME > Technical > Equipment technical information >
Equipment technical information

500KW -750KW IF power cabinet configuration list

Time: 2019-08-21

500KW -750KW IF power cabinet configuration list

IF power supply: 500KW

Rectifier thyristor: KP1000A 1600V   six radiators: S13 double body three sets

Absorption Capacitor: 0.22 μ F 2000V Six Resistors: 50W 20 Ω Six

Inverter thyristor: KK1000A 1600V   eight radiators: S13 double body four sets

Absorption capacitor: 0.47 μ F 2000V eight resistors: no sense 100W 20 Ω eight

Voltage equalization resistance: 100W 10K eight screws: M10*25

Air switch: 1500A

Reactor: core specification Coil: Φ 16 tube turns Φ 220 14 coils

Incoming inductance: Φ 14 tube 10 turns     copper row: × 50 

Inverse transformation to inductance: Φ 14 tube turns   copper row: × 50

Instrument: AC voltmeter 450V   DC voltmeter 600V 

Medium frequency voltmeter 1000V 1000/100 ) Frequency meter 2000Hz 2mA )  

DC ammeter 1000A 75mV ) shunt: 1000A 

      Power meter 600KW 1000/100V 600/5A )

Main control board: J8.1   pulse transformer board: magnetic ring production four

Power transformer: 380/220 / 18V one 

IF transformer: 1000/100/50/20V one 0.22 μ F 2000V one

Current transformer: 1000/5A two   5/0.1A two

Door panel: indicator light LD11 yellow, green, red one ( 220V )  4.7K power potentiometer

Button: LAY3 red one, knob: LAY3 green two

 

IF Power Power 750KW (Line 380V )

Rectifier thyristor: KP1500A 1600V   six radiators: S14 double body three sets

Absorption Capacitor: 0.22 μ F 2000V Six Resistors: 50W 20 Ω Six

Inverter thyristor: KK1500A 1600V   eight radiators: S14 double body four sets

Absorption capacitor: 0.47 μ F 2000V eight resistors: no sense 100W 20 Ω eight

Voltage equalization resistance: 100W 10K eight screws: M10*25

Air switch: 1600A

Reactor: core specification Coil: Φ 16 tube turns Φ 220 14 coils

Incoming inductance: Φ 16 tube 10 turns     copper row: × 60 

Inverse transformation to inductance: Φ 16 tube turns   copper row: × 60

Instrument: AC voltmeter 450V   DC voltmeter 600V 

Medium frequency voltmeter 1000V 1000/100 ) Frequency meter 2000Hz 2mA )  

DC ammeter 1500A 75mV ) shunt: 1500A 

      Power meter 800KW 1000/100V 800/5A )

Main control board: J8.1    pulse transformer board: magnetic ring production four

Power transformer: 380/220 / 18V one 

IF transformer: 1000/100/50/20V one 0.22 μ F 2000V one

Current transformer: 1500/5A two   5/0.1A two

Door panel: indicator light LD11 yellow, green, red one ( 220V )  4.7K power potentiometer

Button: LAY3 red one, knob: LAY3 green two

 



Similar Video